Home Page

We Host The Globe

Why SpaceIon?
Our Network / Datacenter
Contact Us
News
Employment
Partnerships/Alliances

AT&T provides SpaceIon with a carrier class facility in which we house our Internet infrastructure such as servers, firewalls, routers, switches, etc. This facility is characterized by redundant power, environmental controls and security systems to ensure maximum reliability and performance of Internet applications.

Locations
+ NYC, New York
+ Clifton, New Jersey
+ Newark, New Jersey

Datacenter Specifications

  • Cisco P-NAP technology integrated into the facility
  • High Security Environment
    • 24x7 dedicated professional security staff
    • Multiple layers of hard line physical security
    • Multiple layers of electronically controlled access
    • Video surveillance throughout facility
    • Digital storage of all events and video maintained
    • Caged environment
  • Environmental Controls
    • 2,750KVA of robust, conditioned, redundant, expandable, highest quality of AC power
    • Two 20-amp AC circuit provided per cabinet
    • Additional 120V circuits available
    • 208V circuits available
    • Diverse power source feeds available
    • Isolated-redundant UPS configuration- providing industry's highest MTBF
    • Four Liebert 600 series UPS systems
      (3-759KVA & 1-500KVA) for N+2 redundancy
    • 5750kw of redundant Generator backup with a 30hour fuel supply and extended refuel contracts
  • Massive building grounding system
    • Broadcast quality, zero-reference ground integrated throughout facility
    • All cabinets and rack bases bonded to ground
  • 680 tons of robust, redundant, expandable HVAC system
    • 24 Liebert HVAC units (20-30 ton & 4-20 ton units) for N+1 redundancy
    • Liebert rooftop glycol drycooler units for N+1 redundancy
    • Floor water dams with liquid sensors
  • 28" B-Line seismic collocation cabinets are facility standard
    • Accommodating a 19" or 23" rail installation
    • Shelves available
  • Fire detection/prevention
    • VESDA Laser based particulate matter detectors throughout ICC
    • Zone dry-piped pre-action sprinkler system
  • Automated monitoring of power and environmental systems
    • HVAC systems
    • UPS systems
    • Fire detection systems
    • Hourly roving patrol to verify automated reports
  • Open floor plan
    • Maximum use of Connectivity Center area
    • HVAC delivered overhead
    • Power delivered overhead
  • Overhead cable management
    • 24" ladder racking throughout facility for connectivity services
    • 18" ladder racking throughout facility for cabinet to cabinet use
    • 4' ADC fiber tray throughout facility
  • Connectivity: (Available carriers)
    • Verizon
    • AT&T
    • MCI
    • Global NAPS
    • Qwest
    • Global Crossing
  • Building diversity
    • Diverse building entrance facilities
    • Diverse building power rises
    • Dedicated carrier rooms
Copyright © 2005-2008 SpaceIon, Inc. - All Rights Reserved
Jump To:
Quick Links: Company : Clients : Services : Hosting : Support

Print This Page : Bookmark This Page : Email This Page